Hydraulic and Pneumatic Power Systems A pilot reports that when the hydraulic pump is running, the pressure is normal. However, when the pump is stopped, no hydraulic pressure is available. This is an indication of a a. leaking selector valve. b. low accumulator fluid preload. c. leaking accumulator air valve.